The SentryumActive-Act 30kVA UPS is a high-performance‚ three-phase uninterruptible power supply designed for critical applications. It offers exceptional efficiency‚ reaching up to 96.5%‚ and features advanced components like a dual-core DSP processor and high-frequency inverters. Compact and reliable‚ it ensures superior power protection with minimal energy loss.
Key Features and Technical Specifications
The SentryumActive-Act 30kVA UPS offers up to 96.5% efficiency‚ unity power factor‚ and operates in online double conversion mode. It features a dual-core DSP processor‚ high-frequency inverters‚ and supports 1 or 2 internal battery strings. Input voltage is 380/400/415V‚ with a compact footprint and advanced communication ports.
2.1. Models (ACT‚ XTend‚ Compact)
The SentryumActive-Act 30kVA UPS is available in three distinct models: ACT‚ XTend‚ and Compact. The ACT model offers a footprint of less than 0.35m²‚ supports 1 or 2 internal battery strings‚ and is ideal for applications requiring high efficiency and space-saving design. The XTend model provides a larger footprint of up to 0.4m²‚ supporting up to 3 internal battery strings‚ making it suitable for applications needing extended backup capabilities. The Compact model‚ available only for lower power ratings (10-20kVA)‚ offers a highly efficient and space-optimized solution‚ perfect for smaller installations. Each model is designed to cater to specific power requirements and battery autonomy needs‚ ensuring flexibility and reliability across various applications. The ACT and XTend models are particularly popular for their scalability and performance in data centers and critical infrastructure.
Installation and Setup
Proper installation of the SentryumActive-Act 30kVA UPS requires careful site selection and environmental considerations. Ensure the location is well-ventilated‚ away from direct sunlight‚ and has a stable floor. Follow the manual’s guidelines for unpacking‚ positioning‚ and connecting the unit to power sources and batteries. Initial setup includes configuring nominal battery capacity and verifying all connections before powering up.
3.1. Site Selection and Environment
Selecting the right location for the SentryumActive-Act 30kVA UPS is crucial for optimal performance and reliability. The unit should be installed in a well-ventilated‚ temperature-controlled environment‚ ideally between 20°C and 40°C‚ to ensure proper cooling and prevent overheating. Avoid areas with high humidity or moisture‚ as this can damage the electronics. The floor should be stable and level to maintain balance and prevent vibration. Additionally‚ the UPS should be placed away from direct sunlight and sources of electromagnetic interference.
- Ensure proximity to a reliable power source and battery storage area.
- Keep the UPS away from flammable materials and chemicals.
- Provide adequate space around the unit for maintenance and airflow.
Following these guidelines will ensure a safe and efficient installation‚ maximizing the lifespan of the UPS and its components. Always refer to the manual for specific environmental recommendations and safety precautions.
Operational Modes and Efficiency
The SentryumActive-Act 30kVA UPS operates in online double conversion mode‚ ensuring exceptional power quality and efficiency. This mode converts input AC power to DC‚ then back to AC‚ providing a stable and clean output. The system achieves remarkable efficiency of up to 96.5%‚ even at partial loads‚ minimizing energy losses and reducing operating costs. Additionally‚ the UPS supports a power factor of 1‚ allowing full-rated power delivery without de-rating.
- High Efficiency: Up to 96.5% efficiency reduces energy consumption and operational expenses.
- True Online Double Conversion: Ensures consistent power quality and protection against input anomalies.
- Unity Power Factor: Delivers full-rated power‚ optimizing performance for modern loads.
These operational modes and efficiency features make the SentryumActive-Act 30kVA UPS an ideal choice for data centers and critical applications requiring reliable‚ high-performance power protection.
Maintenance and Battery Management
Regular maintenance is crucial for ensuring the optimal performance and longevity of the SentryumActive-Act 30kVA UPS. The system is designed with ease of maintenance in mind‚ featuring accessible components and advanced monitoring capabilities. Battery management is particularly important‚ as the UPS relies on its battery strings to provide backup power during outages.
- Battery Charger: The UPS includes a built-in battery charger that provides a standard current of 6 Amps‚ ensuring batteries are always ready for operation.
- Internal Battery Strings: The ACT model supports 1 or 2 internal battery strings‚ while the XTend model can accommodate up to 3 strings in a single cabinet for extended autonomy.
- Monitoring and Alerts: Advanced communication ports (USB‚ RS232‚ RJ10) enable real-time monitoring of battery health and UPS performance‚ allowing for proactive maintenance.
- Environmental Factors: The UPS is designed to operate efficiently in temperatures up to 40°C‚ but ideal conditions for battery longevity are between 20-25°C and 50% humidity.
Regular checks of the battery terminals‚ electrolyte levels (if applicable)‚ and charging cycles are recommended. The UPS also supports remote monitoring and software updates‚ ensuring optimal performance and reliability over time.
Troubleshooting Common Issues
Troubleshooting the SentryumActive-Act 30kVA UPS involves identifying and resolving common issues promptly to ensure uninterrupted power protection. The system is designed with advanced diagnostics and clear indicators to simplify this process.
- UPS Not Turning On: Check the mains power supply‚ battery connections‚ and ensure the manual bypass switch is in the correct position. Verify that the UPS is properly configured and switched on.
- Battery Issues: Low battery capacity or faulty batteries can trigger alarms. Test battery voltage‚ charge levels‚ and ensure the charger is functioning correctly. Replace batteries if necessary.
- Overload Conditions: If the UPS overloaded‚ reduce the connected load or upgrade to a higher capacity model. The system will alert you if the load exceeds safe levels.
- Communication Errors: Ensure all communication ports (USB‚ RS232‚ RJ10) are securely connected. Restart the UPS and check for firmware updates to resolve connectivity issues.
The UPS features a manual bypass switch to isolate the unit for maintenance without interrupting power to the load. Always refer to the installation manual for detailed troubleshooting steps and safety precautions. Regular maintenance and battery checks can prevent many of these issues‚ ensuring reliable operation and extending the system’s lifespan.
The SentryumActive-Act 30kVA UPS stands out as a top-tier solution for critical power protection‚ offering exceptional efficiency‚ reliability‚ and flexibility. With its advanced double-conversion technology and high-efficiency operation‚ it ensures minimal energy loss while delivering stable power. Designed for demanding environments‚ it is ideal for data centers‚ industrial applications‚ and other mission-critical systems. The availability of models like ACT‚ XTend‚ and Compact caters to diverse needs‚ making it a versatile choice. The comprehensive manual provides clear guidance for installation‚ operation‚ and troubleshooting‚ ensuring users can maximize its capabilities. Overall‚ the SentryumActive-Act 30kVA UPS is a robust and efficient solution‚ backed by reliable support‚ making it a recommended choice for those seeking superior power protection and performance. Its durability and adaptability ensure long-term value‚ solidifying its reputation as a leader in UPS technology.